{"id":4507,"date":"2026-07-03T11:51:05","date_gmt":"2026-07-03T09:51:05","guid":{"rendered":"https:\/\/simuneer.de\/uncategorized\/prediction-of-the-resistance-curve-of-a-planing-hull-fidelity-marine-marintek\/"},"modified":"2026-07-06T13:18:18","modified_gmt":"2026-07-06T11:18:18","slug":"prediction-of-the-resistance-curve-of-a-planing-hull-fidelity-marine-marintek","status":"publish","type":"post","link":"https:\/\/simuneer.de\/en\/case-studies\/marine\/prediction-of-the-resistance-curve-of-a-planing-hull-fidelity-marine-marintek\/","title":{"rendered":"Prediction of the resistance curve of a planing hull Fidelity Marine Marintek"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">For the prediction of the resistance curve of a planing hull and validation against model tests, Marintek used Fidelity Marine and Hexpress in this user case.<\/p>\n\n<p class=\"wp-block-paragraph\">The Norwegian Marine Technology Research Institute (MARINTEK) performs R&amp;D in ocean technology for a global market, primarily in the maritime and oil and gas sectors and ocean energy. MARINTEK&#8217;s main offices and laboratories are located in Trondheim, Norway. A rational combination of physical and numerical modelling approaches has always been MARINTEK\u2019s strategy in its research activities and commercial services. Prediction of vessel and propeller performances, design optimisation process, wake analyses and studies on propulsor-hull interaction are just a few examples of CFD applied to ship hydrodynamics.   <\/p>\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/www.sintef.no\/marintek\" target=\"_blank\" rel=\"noreferrer noopener nofollow\">More about Marintek<\/a><\/p>\n\n<p class=\"wp-block-paragraph\">STM was established in 1991 by the decree of the Defence Industry Executive Committee to provide system engineering, technical support, project management, technology transfer and logistics support services for Turkish Armed Forces (TAF) and Undersecretariat for Defence Industries (SSM) and also develop necessary software technologies for defence systems and establish\/operate national software centres for software development, maintenance\/support.  <br\/><br\/><a href=\"https:\/\/www.stm.com.tr\/en\/\" target=\"_blank\" rel=\"noreferrer noopener nofollow\">More about STM<\/a><\/p>\n\n<h2 class=\"wp-block-heading\">User Case<\/h2>\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-7387b849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"wp-block-paragraph\">The total ship resistance of a new patrol vessel in calm water conditions was evaluated by means of CFD simulations and model tests. The hull form was developed by STM and has as main dimensions: <\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-table has-medium-font-size\"><table class=\"has-white-color has-text-color has-background has-link-color has-fixed-layout\" style=\"background:linear-gradient(35deg,rgb(36,30,70) 0%,rgb(101,30,232) 100%)\"><tbody><tr><td>Length<\/td><td>LPP<\/td><td>[m]<\/td><td>56.1<\/td><\/tr><tr><td>Breadth<\/td><td>B<\/td><td>[m]<\/td><td>8.63<\/td><\/tr><tr><td>Draught<\/td><td>T<\/td><td>[m]<\/td><td>1.68<\/td><\/tr><\/tbody><\/table><\/figure>\n<\/div>\n<\/div>\n\n<p class=\"wp-block-paragraph\">The primary objective of this case study was to validate the numerical model against model tests in order to guaranty high level of accuracy to the End Client in the subsequent numerical phases of the project. CFD and model test predictions were compared for three speeds: 20, 45 and 55 knots. <\/p>\n\n<h2 class=\"wp-block-heading\">CFD Simulations<\/h2>\n\n<p class=\"wp-block-paragraph\">The total resistance of the hull is computed by means of CFD simulations at different speeds. The simulations were performed with Fidelity Marine at full scale, in deep water conditions, in sea water. <\/p>\n\n<p class=\"wp-block-paragraph\">The vessel&#8217;s geometry is meshed using Hexpress. A boundary layer grid normal to the hull surface is specified in order to reach y+ values between 30 and 80. Given the diversity of Froude regime covered in this study, new meshes were generated for each computed speed. Adaptive grid refinement was used with the free surface criterion in the proximity of the hull in the final stage of each simulation in order to increase the accuracy of the results. The final meshes were composed of between 5.0 and 7.5 million cells.    <\/p>\n\n<p class=\"wp-block-paragraph\">In the simulations, the propulsion was modelled as a force applied at the centre of action of the water jets. The air drag was modelled as a force applied at the centre of the frontal projected area. <\/p>\n\n<figure class=\"wp-block-image size-large\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1024\" height=\"611\" src=\"https:\/\/simuneer.de\/wp-content\/uploads\/2026\/07\/Abbildung-1-Wellenbild-bei-einer-Geschwindigkeit-von-55-kn-1024x611.webp\" alt=\"Wave pattern at 55 knots\" class=\"wp-image-4459\" srcset=\"https:\/\/simuneer.de\/wp-content\/uploads\/2026\/07\/Abbildung-1-Wellenbild-bei-einer-Geschwindigkeit-von-55-kn-1024x611.webp 1024w, https:\/\/simuneer.de\/wp-content\/uploads\/2026\/07\/Abbildung-1-Wellenbild-bei-einer-Geschwindigkeit-von-55-kn-300x179.webp 300w, https:\/\/simuneer.de\/wp-content\/uploads\/2026\/07\/Abbildung-1-Wellenbild-bei-einer-Geschwindigkeit-von-55-kn-768x458.webp 768w, https:\/\/simuneer.de\/wp-content\/uploads\/2026\/07\/Abbildung-1-Wellenbild-bei-einer-Geschwindigkeit-von-55-kn-1536x917.webp 1536w, https:\/\/simuneer.de\/wp-content\/uploads\/2026\/07\/Abbildung-1-Wellenbild-bei-einer-Geschwindigkeit-von-55-kn.webp 1580w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">Figure 1: Wave pattern at 55 knots<\/figcaption><\/figure>\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"890\" height=\"654\" src=\"https:\/\/simuneer.de\/wp-content\/uploads\/2026\/07\/Abbildung-2-Bugwellenprofile-an-ausgewaehlten-Rumpfstationen-und-hydrodynamische-Druckverteilung-auf-dem-Rumpf-bei-55-kn-1.webp\" alt=\"Bow wave profile at various hull stations and hydrodynamic pressure on the hull at 55 knots\" class=\"wp-image-4460\" srcset=\"https:\/\/simuneer.de\/wp-content\/uploads\/2026\/07\/Abbildung-2-Bugwellenprofile-an-ausgewaehlten-Rumpfstationen-und-hydrodynamische-Druckverteilung-auf-dem-Rumpf-bei-55-kn-1.webp 890w, https:\/\/simuneer.de\/wp-content\/uploads\/2026\/07\/Abbildung-2-Bugwellenprofile-an-ausgewaehlten-Rumpfstationen-und-hydrodynamische-Druckverteilung-auf-dem-Rumpf-bei-55-kn-1-300x220.webp 300w, https:\/\/simuneer.de\/wp-content\/uploads\/2026\/07\/Abbildung-2-Bugwellenprofile-an-ausgewaehlten-Rumpfstationen-und-hydrodynamische-Druckverteilung-auf-dem-Rumpf-bei-55-kn-1-768x564.webp 768w\" sizes=\"(max-width: 890px) 100vw, 890px\" \/><figcaption class=\"wp-element-caption\">Figure 2: Bow wave profile at various hull stations and hydrodynamic pressure on the hull at 55 knots<\/figcaption><\/figure>\n\n<h2 class=\"wp-block-heading\">Model Tests<\/h2>\n\n<p class=\"wp-block-paragraph\">The hull model is made of foam and wood coated with paint with a hydrodynamically smooth surface finish to the linear scale of 1:16. For turbulence stimulation, fine sand grains were glued to the hull along the keel from bow to station 17. <\/p>\n\n<p class=\"wp-block-paragraph\">The resistance tests were performed with the model towed by MARINTEK&#8217;s high speed rig with measurements of resistance, trim and sinkage. In the model test setup, the model is free to heave, roll and trim but fixed in all other degrees of freedom. <\/p>\n\n<p class=\"wp-block-paragraph\">The effect of air drag on the projected area above water line are included in the predictions based on the projected area of the vessel.<\/p>\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-7387b849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"1024\" height=\"507\" src=\"https:\/\/simuneer.de\/wp-content\/uploads\/2026\/07\/Abbildung-3-Unteransicht-des-Rumpfes-mit-zugehoerigem-Wellenbild-1024x507.webp\" alt=\"Bottom view of the hull and wave pattern\" class=\"wp-image-4461\" srcset=\"https:\/\/simuneer.de\/wp-content\/uploads\/2026\/07\/Abbildung-3-Unteransicht-des-Rumpfes-mit-zugehoerigem-Wellenbild-1024x507.webp 1024w, https:\/\/simuneer.de\/wp-content\/uploads\/2026\/07\/Abbildung-3-Unteransicht-des-Rumpfes-mit-zugehoerigem-Wellenbild-300x149.webp 300w, https:\/\/simuneer.de\/wp-content\/uploads\/2026\/07\/Abbildung-3-Unteransicht-des-Rumpfes-mit-zugehoerigem-Wellenbild-768x381.webp 768w, https:\/\/simuneer.de\/wp-content\/uploads\/2026\/07\/Abbildung-3-Unteransicht-des-Rumpfes-mit-zugehoerigem-Wellenbild-1536x761.webp 1536w, https:\/\/simuneer.de\/wp-content\/uploads\/2026\/07\/Abbildung-3-Unteransicht-des-Rumpfes-mit-zugehoerigem-Wellenbild.webp 1538w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">Figure 3: Bottom view of the hull and wave pattern<\/figcaption><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"682\" src=\"https:\/\/simuneer.de\/wp-content\/uploads\/2026\/07\/Abbildung-4-Perspektivische-Ansicht-des-Rumpfes-mit-zugehoerigem-Wellenbild-1024x682.webp\" alt=\"Perspective view of the hull and wave pattern\" class=\"wp-image-4462\" srcset=\"https:\/\/simuneer.de\/wp-content\/uploads\/2026\/07\/Abbildung-4-Perspektivische-Ansicht-des-Rumpfes-mit-zugehoerigem-Wellenbild-1024x682.webp 1024w, https:\/\/simuneer.de\/wp-content\/uploads\/2026\/07\/Abbildung-4-Perspektivische-Ansicht-des-Rumpfes-mit-zugehoerigem-Wellenbild-300x200.webp 300w, https:\/\/simuneer.de\/wp-content\/uploads\/2026\/07\/Abbildung-4-Perspektivische-Ansicht-des-Rumpfes-mit-zugehoerigem-Wellenbild-768x512.webp 768w, https:\/\/simuneer.de\/wp-content\/uploads\/2026\/07\/Abbildung-4-Perspektivische-Ansicht-des-Rumpfes-mit-zugehoerigem-Wellenbild.webp 1144w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">Figure 4: Perspective view of the hull and wave pattern<\/figcaption><\/figure>\n<\/div>\n<\/div>\n\n<h2 class=\"wp-block-heading\">Conversion to Total Ship Resistance<\/h2>\n\n<p class=\"wp-block-paragraph\">The conversion from hull model (numerical or experimental) into full scale ship is made by using the form factor method. In this method, it is assumed that the total resistance can be divided into two parts, represented by the viscous resistance and the residuary (due to vorticity, wave making and wave breaking) resistance CR. The viscous resistance is determined by multiplying the frictional resistance CF with a constant form factor k0, which is identical for the models and the ship. Further, it is assumed that the residuary resistance CR is identical for models and the ship.   <\/p>\n\n<p class=\"wp-block-paragraph\">When numerical or experimental results are converted to total ship resistance RTs, the effect of the hull surface roughness is taken into account by means of empirical formula. The results are presented in terms of non-dimensional total ship resistance CTs, in which the dimensionalisation is performed using the dynamic wetted length and surface of the vessel. <\/p>\n\n<h2 class=\"wp-block-heading\">Results<\/h2>\n\n<p class=\"wp-block-paragraph\">The following table compares the predicted total ship resistance obtained from the model test approach and the CFD approach. For all speeds, the results agree within 0.7 %. The hydrodynamic trim angle agrees within 0.5 deg. This is a satisfying result, given that trim measurements are not corrected for scale effects and that the CFD mesh could be even further refined around the hull to address more accurately this application, which was not necessary in this study.   <\/p>\n\n<figure class=\"wp-block-table has-medium-font-size\"><table class=\"has-white-color has-text-color has-background has-link-color has-fixed-layout\" style=\"background:linear-gradient(35deg,rgb(36,30,70) 0%,rgb(101,30,232) 100%)\"><tbody><tr><td> <\/td><td> <\/td><td colspan=\"2\"><strong>Model tests<\/strong><\/td><td colspan=\"2\"><strong>CFD<\/strong><\/td><\/tr><tr><td><strong>VS [knots]<\/strong><\/td><td><strong>FN [-]<\/strong><\/td><td><strong>CTS [-]<\/strong><\/td><td><strong>Trim [deg]<\/strong><\/td><td><strong>CTS [-] (%)<\/strong><\/td><td><strong>Trim [deg] (Delta)<\/strong><\/td><\/tr><tr><td>20.0<\/td><td>0.439<\/td><td>8.64<\/td><td>0.74<\/td><td>8.70 (+0.7%)<\/td><td>0.64 (-0.10)<\/td><\/tr><tr><td>45.0<\/td><td>0.998<\/td><td>4.41<\/td><td>1.66<\/td><td>4.38 (-0.7%)<\/td><td>1.32 (-0.34)<\/td><\/tr><tr><td>55.0<\/td><td>1.226<\/td><td>3.66<\/td><td>2.27<\/td><td>3.64 (-0.5%)<\/td><td>1.75 (-0.52)<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-7387b849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"917\" height=\"780\" src=\"https:\/\/simuneer.de\/wp-content\/uploads\/2026\/07\/Abbildung-5-Vergleich-der-Modellversuchsergebnisse-mit-den-CFD-Ergebnissen-hinsichtlich-des-dimensionslosen-Gesamtwiderstandsbeiwerts-CTs.webp\" alt=\"Comparison of model test results with CFD results in terms of non-dimensional total ship resistance CTs\" class=\"wp-image-4463\" srcset=\"https:\/\/simuneer.de\/wp-content\/uploads\/2026\/07\/Abbildung-5-Vergleich-der-Modellversuchsergebnisse-mit-den-CFD-Ergebnissen-hinsichtlich-des-dimensionslosen-Gesamtwiderstandsbeiwerts-CTs.webp 917w, https:\/\/simuneer.de\/wp-content\/uploads\/2026\/07\/Abbildung-5-Vergleich-der-Modellversuchsergebnisse-mit-den-CFD-Ergebnissen-hinsichtlich-des-dimensionslosen-Gesamtwiderstandsbeiwerts-CTs-300x255.webp 300w, https:\/\/simuneer.de\/wp-content\/uploads\/2026\/07\/Abbildung-5-Vergleich-der-Modellversuchsergebnisse-mit-den-CFD-Ergebnissen-hinsichtlich-des-dimensionslosen-Gesamtwiderstandsbeiwerts-CTs-768x653.webp 768w\" sizes=\"(max-width: 917px) 100vw, 917px\" \/><figcaption class=\"wp-element-caption\">Figure 5: Comparison of model test results with CFD results in terms of non-dimensional total ship resistance CTs<\/figcaption><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"960\" height=\"816\" src=\"https:\/\/simuneer.de\/wp-content\/uploads\/2026\/07\/Abbildung-6-Vergleich-der-Modellversuchsergebnisse-mit-den-CFD-Ergebnissen-hinsichtlich-des-hydrodynamischen-Trimmwinkels.webp\" alt=\"Comparison of model test results with CFD results in terms of hydrodynamic trim angle\" class=\"wp-image-4464\" srcset=\"https:\/\/simuneer.de\/wp-content\/uploads\/2026\/07\/Abbildung-6-Vergleich-der-Modellversuchsergebnisse-mit-den-CFD-Ergebnissen-hinsichtlich-des-hydrodynamischen-Trimmwinkels.webp 960w, https:\/\/simuneer.de\/wp-content\/uploads\/2026\/07\/Abbildung-6-Vergleich-der-Modellversuchsergebnisse-mit-den-CFD-Ergebnissen-hinsichtlich-des-hydrodynamischen-Trimmwinkels-300x255.webp 300w, https:\/\/simuneer.de\/wp-content\/uploads\/2026\/07\/Abbildung-6-Vergleich-der-Modellversuchsergebnisse-mit-den-CFD-Ergebnissen-hinsichtlich-des-hydrodynamischen-Trimmwinkels-768x653.webp 768w\" sizes=\"(max-width: 960px) 100vw, 960px\" \/><figcaption class=\"wp-element-caption\">Figure 6: Comparison of model test results with CFD results in terms of hydrodynamic trim angle<\/figcaption><\/figure>\n<\/div>\n<\/div>\n\n<h2 class=\"wp-block-heading\">Conclusions<\/h2>\n\n<p class=\"wp-block-paragraph\">The excellent agreement between the model tests and CFD predictions for the total ship resistance in calm water condition results in a good confidence level in the CFD results presented to the end client.<\/p>\n\n<h2 class=\"wp-block-heading\">Meet the Team<\/h2>\n\n<ul class=\"wp-block-list\">\n<li>End User \u2013 Elo\u00efse Croonenborghs, Research Scientist at MARINTEK, Maritime division, Trondheim, Norway<\/li>\n\n\n\n<li>Team Expert \u2013 Sverre Anders Alterskj\u00e6r, Research Scientist at MARINTEK, Maritime division, Trondheim, Norway<\/li>\n\n\n\n<li>End Client Expert \u2013 Canan TIRYAKI, STM, Ankara, Turkey<\/li>\n\n\n\n<li>Software Provider \u2013 Cadence Design Systems, Inc.<\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>For the prediction of the resistance curve of a planing hull and validation against model tests, Marintek used Fidelity Marine and Hexpress in this user case.<\/p>\n","protected":false},"author":9,"featured_media":4473,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[67,72],"tags":[],"class_list":["post-4507","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-case-studies","category-marine"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.0 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Prediction of the resistance curve of a planing hull Fidelity Marine Marintek | Simuneer<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/simuneer.de\/en\/case-studies\/marine\/prediction-of-the-resistance-curve-of-a-planing-hull-fidelity-marine-marintek\/\" \/>\n<meta property=\"og:locale\" content=\"en_GB\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Prediction of the resistance curve of a planing hull Fidelity Marine Marintek | Simuneer\" \/>\n<meta property=\"og:description\" content=\"For the prediction of the resistance curve of a planing hull and validation against model tests, Marintek used Fidelity Marine and Hexpress in this user case.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/simuneer.de\/en\/case-studies\/marine\/prediction-of-the-resistance-curve-of-a-planing-hull-fidelity-marine-marintek\/\" \/>\n<meta property=\"og:site_name\" content=\"Simuneer\" \/>\n<meta property=\"article:published_time\" content=\"2026-07-03T09:51:05+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-07-06T11:18:18+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/simuneer.de\/wp-content\/uploads\/2026\/07\/Marintek-Planing-Hulls_1728x868.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"1728\" \/>\n\t<meta property=\"og:image:height\" content=\"868\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"author\" content=\"Jessica Jungclaus\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Jessica Jungclaus\" \/>\n\t<meta name=\"twitter:label2\" content=\"Estimated reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"5 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/simuneer.de\\\/en\\\/case-studies\\\/marine\\\/prediction-of-the-resistance-curve-of-a-planing-hull-fidelity-marine-marintek\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/simuneer.de\\\/en\\\/case-studies\\\/marine\\\/prediction-of-the-resistance-curve-of-a-planing-hull-fidelity-marine-marintek\\\/\"},\"author\":{\"name\":\"Jessica Jungclaus\",\"@id\":\"https:\\\/\\\/simuneer.de\\\/en\\\/#\\\/schema\\\/person\\\/9262b7843394b469fe0e321b14936597\"},\"headline\":\"Prediction of the resistance curve of a planing hull Fidelity Marine Marintek\",\"datePublished\":\"2026-07-03T09:51:05+00:00\",\"dateModified\":\"2026-07-06T11:18:18+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/simuneer.de\\\/en\\\/case-studies\\\/marine\\\/prediction-of-the-resistance-curve-of-a-planing-hull-fidelity-marine-marintek\\\/\"},\"wordCount\":960,\"publisher\":{\"@id\":\"https:\\\/\\\/simuneer.de\\\/en\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/simuneer.de\\\/en\\\/case-studies\\\/marine\\\/prediction-of-the-resistance-curve-of-a-planing-hull-fidelity-marine-marintek\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/simuneer.de\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/Marintek-Planing-Hulls_1728x868.webp\",\"articleSection\":[\"Case Studies\",\"Marine\"],\"inLanguage\":\"en-GB\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/simuneer.de\\\/en\\\/case-studies\\\/marine\\\/prediction-of-the-resistance-curve-of-a-planing-hull-fidelity-marine-marintek\\\/\",\"url\":\"https:\\\/\\\/simuneer.de\\\/en\\\/case-studies\\\/marine\\\/prediction-of-the-resistance-curve-of-a-planing-hull-fidelity-marine-marintek\\\/\",\"name\":\"Prediction of the resistance curve of a planing hull Fidelity Marine Marintek | Simuneer\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/simuneer.de\\\/en\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/simuneer.de\\\/en\\\/case-studies\\\/marine\\\/prediction-of-the-resistance-curve-of-a-planing-hull-fidelity-marine-marintek\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/simuneer.de\\\/en\\\/case-studies\\\/marine\\\/prediction-of-the-resistance-curve-of-a-planing-hull-fidelity-marine-marintek\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/simuneer.de\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/Marintek-Planing-Hulls_1728x868.webp\",\"datePublished\":\"2026-07-03T09:51:05+00:00\",\"dateModified\":\"2026-07-06T11:18:18+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/simuneer.de\\\/en\\\/case-studies\\\/marine\\\/prediction-of-the-resistance-curve-of-a-planing-hull-fidelity-marine-marintek\\\/#breadcrumb\"},\"inLanguage\":\"en-GB\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/simuneer.de\\\/en\\\/case-studies\\\/marine\\\/prediction-of-the-resistance-curve-of-a-planing-hull-fidelity-marine-marintek\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-GB\",\"@id\":\"https:\\\/\\\/simuneer.de\\\/en\\\/case-studies\\\/marine\\\/prediction-of-the-resistance-curve-of-a-planing-hull-fidelity-marine-marintek\\\/#primaryimage\",\"url\":\"https:\\\/\\\/simuneer.de\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/Marintek-Planing-Hulls_1728x868.webp\",\"contentUrl\":\"https:\\\/\\\/simuneer.de\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/Marintek-Planing-Hulls_1728x868.webp\",\"width\":1728,\"height\":868},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/simuneer.de\\\/en\\\/case-studies\\\/marine\\\/prediction-of-the-resistance-curve-of-a-planing-hull-fidelity-marine-marintek\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Start\",\"item\":\"https:\\\/\\\/simuneer.de\\\/en\\\/home\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Prediction of the resistance curve of a planing hull Fidelity Marine Marintek\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/simuneer.de\\\/en\\\/#website\",\"url\":\"https:\\\/\\\/simuneer.de\\\/en\\\/\",\"name\":\"Simuneer\",\"description\":\"Starke Software, starke Ergebnisse\",\"publisher\":{\"@id\":\"https:\\\/\\\/simuneer.de\\\/en\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/simuneer.de\\\/en\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-GB\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/simuneer.de\\\/en\\\/#organization\",\"name\":\"Simuneer\",\"url\":\"https:\\\/\\\/simuneer.de\\\/en\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-GB\",\"@id\":\"https:\\\/\\\/simuneer.de\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/simuneer.de\\\/wp-content\\\/uploads\\\/2025\\\/10\\\/SIM-Logo_RGB_White.svg\",\"contentUrl\":\"https:\\\/\\\/simuneer.de\\\/wp-content\\\/uploads\\\/2025\\\/10\\\/SIM-Logo_RGB_White.svg\",\"width\":607,\"height\":119,\"caption\":\"Simuneer\"},\"image\":{\"@id\":\"https:\\\/\\\/simuneer.de\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/simuneer.de\\\/en\\\/#\\\/schema\\\/person\\\/9262b7843394b469fe0e321b14936597\",\"name\":\"Jessica Jungclaus\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-GB\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/7a27374fc821e470875a14bb7a2c1edbb75e716b3227255dfd75a85b20eb1346?s=96&d=initials&r=g&initials=JJ\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/7a27374fc821e470875a14bb7a2c1edbb75e716b3227255dfd75a85b20eb1346?s=96&d=initials&r=g&initials=JJ\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/7a27374fc821e470875a14bb7a2c1edbb75e716b3227255dfd75a85b20eb1346?s=96&d=initials&r=g&initials=JJ\",\"caption\":\"Jessica Jungclaus\"},\"url\":\"https:\\\/\\\/simuneer.de\\\/en\\\/author\\\/jjungclaus\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Prediction of the resistance curve of a planing hull Fidelity Marine Marintek | Simuneer","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/simuneer.de\/en\/case-studies\/marine\/prediction-of-the-resistance-curve-of-a-planing-hull-fidelity-marine-marintek\/","og_locale":"en_GB","og_type":"article","og_title":"Prediction of the resistance curve of a planing hull Fidelity Marine Marintek | Simuneer","og_description":"For the prediction of the resistance curve of a planing hull and validation against model tests, Marintek used Fidelity Marine and Hexpress in this user case.","og_url":"https:\/\/simuneer.de\/en\/case-studies\/marine\/prediction-of-the-resistance-curve-of-a-planing-hull-fidelity-marine-marintek\/","og_site_name":"Simuneer","article_published_time":"2026-07-03T09:51:05+00:00","article_modified_time":"2026-07-06T11:18:18+00:00","og_image":[{"width":1728,"height":868,"url":"https:\/\/simuneer.de\/wp-content\/uploads\/2026\/07\/Marintek-Planing-Hulls_1728x868.webp","type":"image\/webp"}],"author":"Jessica Jungclaus","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Jessica Jungclaus","Estimated reading time":"5 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/simuneer.de\/en\/case-studies\/marine\/prediction-of-the-resistance-curve-of-a-planing-hull-fidelity-marine-marintek\/#article","isPartOf":{"@id":"https:\/\/simuneer.de\/en\/case-studies\/marine\/prediction-of-the-resistance-curve-of-a-planing-hull-fidelity-marine-marintek\/"},"author":{"name":"Jessica Jungclaus","@id":"https:\/\/simuneer.de\/en\/#\/schema\/person\/9262b7843394b469fe0e321b14936597"},"headline":"Prediction of the resistance curve of a planing hull Fidelity Marine Marintek","datePublished":"2026-07-03T09:51:05+00:00","dateModified":"2026-07-06T11:18:18+00:00","mainEntityOfPage":{"@id":"https:\/\/simuneer.de\/en\/case-studies\/marine\/prediction-of-the-resistance-curve-of-a-planing-hull-fidelity-marine-marintek\/"},"wordCount":960,"publisher":{"@id":"https:\/\/simuneer.de\/en\/#organization"},"image":{"@id":"https:\/\/simuneer.de\/en\/case-studies\/marine\/prediction-of-the-resistance-curve-of-a-planing-hull-fidelity-marine-marintek\/#primaryimage"},"thumbnailUrl":"https:\/\/simuneer.de\/wp-content\/uploads\/2026\/07\/Marintek-Planing-Hulls_1728x868.webp","articleSection":["Case Studies","Marine"],"inLanguage":"en-GB"},{"@type":"WebPage","@id":"https:\/\/simuneer.de\/en\/case-studies\/marine\/prediction-of-the-resistance-curve-of-a-planing-hull-fidelity-marine-marintek\/","url":"https:\/\/simuneer.de\/en\/case-studies\/marine\/prediction-of-the-resistance-curve-of-a-planing-hull-fidelity-marine-marintek\/","name":"Prediction of the resistance curve of a planing hull Fidelity Marine Marintek | Simuneer","isPartOf":{"@id":"https:\/\/simuneer.de\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/simuneer.de\/en\/case-studies\/marine\/prediction-of-the-resistance-curve-of-a-planing-hull-fidelity-marine-marintek\/#primaryimage"},"image":{"@id":"https:\/\/simuneer.de\/en\/case-studies\/marine\/prediction-of-the-resistance-curve-of-a-planing-hull-fidelity-marine-marintek\/#primaryimage"},"thumbnailUrl":"https:\/\/simuneer.de\/wp-content\/uploads\/2026\/07\/Marintek-Planing-Hulls_1728x868.webp","datePublished":"2026-07-03T09:51:05+00:00","dateModified":"2026-07-06T11:18:18+00:00","breadcrumb":{"@id":"https:\/\/simuneer.de\/en\/case-studies\/marine\/prediction-of-the-resistance-curve-of-a-planing-hull-fidelity-marine-marintek\/#breadcrumb"},"inLanguage":"en-GB","potentialAction":[{"@type":"ReadAction","target":["https:\/\/simuneer.de\/en\/case-studies\/marine\/prediction-of-the-resistance-curve-of-a-planing-hull-fidelity-marine-marintek\/"]}]},{"@type":"ImageObject","inLanguage":"en-GB","@id":"https:\/\/simuneer.de\/en\/case-studies\/marine\/prediction-of-the-resistance-curve-of-a-planing-hull-fidelity-marine-marintek\/#primaryimage","url":"https:\/\/simuneer.de\/wp-content\/uploads\/2026\/07\/Marintek-Planing-Hulls_1728x868.webp","contentUrl":"https:\/\/simuneer.de\/wp-content\/uploads\/2026\/07\/Marintek-Planing-Hulls_1728x868.webp","width":1728,"height":868},{"@type":"BreadcrumbList","@id":"https:\/\/simuneer.de\/en\/case-studies\/marine\/prediction-of-the-resistance-curve-of-a-planing-hull-fidelity-marine-marintek\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Start","item":"https:\/\/simuneer.de\/en\/home\/"},{"@type":"ListItem","position":2,"name":"Prediction of the resistance curve of a planing hull Fidelity Marine Marintek"}]},{"@type":"WebSite","@id":"https:\/\/simuneer.de\/en\/#website","url":"https:\/\/simuneer.de\/en\/","name":"Simuneer","description":"Starke Software, starke Ergebnisse","publisher":{"@id":"https:\/\/simuneer.de\/en\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/simuneer.de\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-GB"},{"@type":"Organization","@id":"https:\/\/simuneer.de\/en\/#organization","name":"Simuneer","url":"https:\/\/simuneer.de\/en\/","logo":{"@type":"ImageObject","inLanguage":"en-GB","@id":"https:\/\/simuneer.de\/en\/#\/schema\/logo\/image\/","url":"https:\/\/simuneer.de\/wp-content\/uploads\/2025\/10\/SIM-Logo_RGB_White.svg","contentUrl":"https:\/\/simuneer.de\/wp-content\/uploads\/2025\/10\/SIM-Logo_RGB_White.svg","width":607,"height":119,"caption":"Simuneer"},"image":{"@id":"https:\/\/simuneer.de\/en\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/simuneer.de\/en\/#\/schema\/person\/9262b7843394b469fe0e321b14936597","name":"Jessica Jungclaus","image":{"@type":"ImageObject","inLanguage":"en-GB","@id":"https:\/\/secure.gravatar.com\/avatar\/7a27374fc821e470875a14bb7a2c1edbb75e716b3227255dfd75a85b20eb1346?s=96&d=initials&r=g&initials=JJ","url":"https:\/\/secure.gravatar.com\/avatar\/7a27374fc821e470875a14bb7a2c1edbb75e716b3227255dfd75a85b20eb1346?s=96&d=initials&r=g&initials=JJ","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/7a27374fc821e470875a14bb7a2c1edbb75e716b3227255dfd75a85b20eb1346?s=96&d=initials&r=g&initials=JJ","caption":"Jessica Jungclaus"},"url":"https:\/\/simuneer.de\/en\/author\/jjungclaus\/"}]}},"_links":{"self":[{"href":"https:\/\/simuneer.de\/en\/wp-json\/wp\/v2\/posts\/4507","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/simuneer.de\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/simuneer.de\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/simuneer.de\/en\/wp-json\/wp\/v2\/users\/9"}],"replies":[{"embeddable":true,"href":"https:\/\/simuneer.de\/en\/wp-json\/wp\/v2\/comments?post=4507"}],"version-history":[{"count":0,"href":"https:\/\/simuneer.de\/en\/wp-json\/wp\/v2\/posts\/4507\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/simuneer.de\/en\/wp-json\/wp\/v2\/media\/4473"}],"wp:attachment":[{"href":"https:\/\/simuneer.de\/en\/wp-json\/wp\/v2\/media?parent=4507"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/simuneer.de\/en\/wp-json\/wp\/v2\/categories?post=4507"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/simuneer.de\/en\/wp-json\/wp\/v2\/tags?post=4507"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}